The TX600 spare parts manual is a comprehensive guide that provides detailed information about the spare parts used in the TX600 machinery. It includes a parts list, descriptions, illustrations. It is a valuable resource for technicians and maintenance personnel to effectively repair and maintain the TX600 equipment.
0/3
CP440 Portable Motor Training Manual
About Lesson

4.2    Battery testing

Within this section it will explain the correct procedure on testing  the batteries for servicing procedures or replacement. (To be completed by a competent person)

 

Step 1 – Take the ACT Battery tester out of the packaging and place on a level surface

Step 2 – take the Lead acid 12v 5Ah battery and locate near tester

Step 3 – Attach the positive connector to the positive terminal in below orientation

Step 4 – Attach the positive connector to the positive terminal in below orientation

Step 5 – Wait for the tester to wake up and ensure to set the machine ‘SET Ah Cal’ to “0”

Step 6 – After it has been set the Tester will show you the battery voltage, ensure this is between 12-13 volts

Step 7 – Press the Red button the start the test

Step 8 – the tester will show a Ah reading, ensure this is above 3.0 Ah