Course Content
TX600 – Training Manual
0/1
TX600 – Commissioning Manual
0/35
TX600 – Spare Parts Manual
The TX600 spare parts manual is a comprehensive guide that provides detailed information about the spare parts used in the TX600 machinery. It includes a parts list, descriptions, illustrations. It is a valuable resource for technicians and maintenance personnel to effectively repair and maintain the TX600 equipment.
0/3
Test Topic
TX600 (Fixed Motor)
About Lesson

9.13    Battery Lead Fuse

This section will instruct the correct procedure on how to remove and replace the Battery Lead Fuse.

 

Removal

Step 1 – Remove external covers off the Hoist (refer to section 9.1)

Step 2- Disconnect the power lead from PCB.

Step 3 – Release the Velcro straps (arrowed) to give access to the batteries and power lead terminal.

Step 4 – Detach the power cable from the battery terminal (Arrowed). This is the lead with the fuse which is on the board side of the Hoist.

Step 5 – Remove the Main Power lead to access the Fuse.

Step 6 – Unscrew the Fuse Holder to access and remove the Fuse from the Power Lead.

Refitting / Replacement

Step 8 – Refitting is a reversal of the removal process noting the following points:

1. Make sure the battery terminal are on the outer edge and the terminals are pointing inwards.

2. Ensure the positive lead (Red) goes to the correct side of the Hoist (Arrowed) and the negative lead (Black) goes to the correct side of the Hoist (Arrowed).