The TX600 spare parts manual is a comprehensive guide that provides detailed information about the spare parts used in the TX600 machinery. It includes a parts list, descriptions, illustrations. It is a valuable resource for technicians and maintenance personnel to effectively repair and maintain the TX600 equipment.
0/3
Test Topic
TX600 (Fixed Motor)
About Lesson

9.7    Bottom Cover

This section will instruct the correct procedure on how to remove and replace the Bottom Cover.

 

Removal

Step 1 – Remove external covers of the Hoist. (refer to section 9.1)

Step 2 – Remove QRS Hook. (refer to section 9.6)

Step 3 – Disconnect the power cable from the PCB.

Step 4 – Disconnect the display and LED able from the PCB. (Arrowed)

Step 5 – Gently pull the bottom cover away from the chassis and feed the Lift Tape through to detach it from the unit.

 

Refitting / Replacement

Step 6 – Refitting is a reversal of the removal process noting the following point:

1. Make sure the lift tape is fed through the slot in the correct direction

2. Ensure the E-lower cord is pulled through its designated slot.

3. Ensure the air grommet lines up with the hole.