The TX600 spare parts manual is a comprehensive guide that provides detailed information about the spare parts used in the TX600 machinery. It includes a parts list, descriptions, illustrations. It is a valuable resource for technicians and maintenance personnel to effectively repair and maintain the TX600 equipment.
0/3
Test Topic
TX600 (Fixed Motor)
About Lesson

4.1  Ceiling Track Access

Prior to installing the Trolley into the pre-installed track, the track entrance must first be opened. A pre-installed track should include an end stop, safety bolt and an end cap. If these parts are not installed, it is essential that they are once the Trolley is installed.

Follow the guidance below to remove the ceiling track components. It is recommended that a step ladder is used to perform the task safer and easier.

1. Remove the end cap from the end of the track. 

2. Using two 13mm spanners, loosen the safety bolt and remove the securing nut from the end. 

3. Remove the safety bolt from the track and remove the large rubber bumper held within the track. 

 

 

4. Using a 5mm Allen Key, release the two screws securing the end stop and slide the end stop out of the track.

 

To refit the end stop, safety bolt and end cap, follow the steps above in reverse order noting the following points:

– Ensure the end stop bumper is facing into the ceiling track.

– Ensure all fasteners are secure and cannot come undone without the use of tools.

– When fitting a charging dock, an end stop is not required at that end of the track.

 

(The images in this section all refer to a Track Type 1 installation, but the same process applies for all the remaining track types)